|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
MITSUBISHI GATE TURN-OFF THYRISTORS FG3300AH-50DA HIGH POWER INVERTER USE PRESS PACK TYPE FG3300AH-50DA OUTLINE DRAWING Dimensions in mm GATE (WHITE) 412 8 AUXILIARY CATHODE CONNECTOR (RED) 70 0.2 0.4 MIN 3.5 DEPTH 2.2 0.2 CATHODE TYPE NAME q ITQRM Repetitive controllable on-state current ...........3300A q IT(AV) Average on-state current .....................1000A q VDRM Repetitive peak off state voltage ...................2500V q Anode short type 26 0.5 0.4 MIN 700.2 108 MAX ANODE 3.5 DEPTH 2.2 0.2 APPLICATION Inverters, D.C. choppers, Induction heaters, D.C. to D.C. converters. MAXIMUM RATINGS Symbol VRRM VRSM VR(DC) VDRM VDSM VD(DC) + : VGK = -2V Parameter Repetitive peak reverse voltage Non-repetitive peak reverse voltage DC reverse voltage Repetitive peak off-state voltage+ Non-repetitive peak off-state voltage+ DC off-state voltage+ Parameter Repetitive controllable on-state current RMS on-state current Average on-state current Surge (non-repetitive) on-state current Current-squared, time integration Critical rate of rise of on-state current Peak forward gate voltage Peak reverse gate voltage Peak forward gate current Peak gate reverse current Peak forward gate power dissipation Peak reverse gate power dissipation Average forward gate power dissipation Average reverse gate power dissipation Junction temperature Storage temperature Mounting force required Weight Voltage class 50DA 17 17 17 2500 2500 2000 Conditions VDM = 1875V, Tj = 125C, CS = 6.0F, LS = 0.2H f = 60Hz, sine wave = 180, Tf = 81C One half cycle at 60Hz One cycle at 60Hz VD = 1250V, IGM = 40A, Tj = 125C Ratings 3300 1570 1000 24 2.4 x 106 500 10 17 100 1100 400 27 100 230 -40 ~ +125 -40 ~ +150 30 ~ 40 1220 Unit V V V V V V Unit A A A kA A2s A/s V V A A W kW W W C C kN g Aug.1998 Symbol ITQRM IT(RMS) IT(AV) ITSM I2t diT/dt VFGM VRGM IFGM IRGM PFGM PRGM PFG(AV) PRG(AV) Tj Tstg -- -- Recommended value 33 Standard value MITSUBISHI GATE TURN-OFF THYRISTORS FG3300AH-50DA HIGH POWER INVERTER USE PRESS PACK TYPE ELECTRICAL CHARACTERISTICS Symbol VTM IRRM IDRM IRG dv/dt tgt tgq IGQM VGT IGT Rth(j-f) Parameter On-state voltage Repetitive peak reverse current Repetitive peak off-state current Reverse gate current Critical rate of rise of off-state voltage Turn-on time Turn-off time Peak gate turn-off current Gate trigger voltage Gate trigger current Thermal resistance Test conditions Tj = 125C, ITM = 3300A, Instantaneous measurment Tj = 125C, VRRM Applied Tj = 125C, VDRM Applied, VGK = -2V Tj = 125C, VRG = 17V Tj = 125C, VD = 1250V, VGK = -2V Tj = 125C, ITM = 3300A, IGM = 40A, VD = 1250V Tj = 125C, ITM = 3300A, VDM = 1875V, diGQ/dt = -40A/s VRG = 17V, CS = 6.0F, LS = 0.2H DC METHOD : VD = 24V, RL = 0.1, Tj = 25C Junction to fin Min -- -- -- -- 1000 -- -- -- -- -- -- Limits Typ -- -- -- -- -- -- -- 780 -- -- -- Max 3.0 300 150 300 -- 10 35 Unit V mA mA mA V/s s s A V mA C/W -- 1.5 4000 0.015 PERFORMANCE CURVES SURGE ON-STATE CURRENT (kA) ON-STATE CURRENT (A) MAXIMUM ON-STATE CHARACTERISTIC 104 7 Tj = 125C 5 3 2 103 7 5 3 2 102 7 5 3 2 101 0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 ON-STATE VOLTAGE (V) RATED SURGE ON-STATE CURRENT 25 20 15 10 5 0 100 23 5 7 101 23 5 7 102 CONDUCTION TIME (CYCLES AT 60Hz) MAXIMUM THERMAL IMPEDANCE CHARACTERISTIC (JUNCTION TO FIN) 100 2 3 5 7101 0.025 THERMAL IMPEDANCE (C/ W) GATE CHARACTERISTICS 102 7 5 3 2 101 7 5 3 2 100 7 5 3 2 PFGM = 400W VFGM = 10V GATE VOLTAGE (V) 0.020 PFG(AV) = 100W VGT = 1.5V 0.015 0.010 Tj = 25C IFGM = 100A IGT = 4000mA 0.005 0 10-3 2 3 5 710-2 2 3 5 710-1 2 3 5 7 100 TIME (S) 10-1 102 2 3 5 7 103 2 3 5 7 104 2 3 5 7 105 GATE CURRENT (mA) Aug.1998 MITSUBISHI GATE TURN-OFF THYRISTORS FG3300AH-50DA HIGH POWER INVERTER USE PRESS PACK TYPE MAXIMUM ON-STATE POWER DISSIPATION CHARACTERISTICS (SINGLE-PHASE HALF WAVE) 5000 4500 4000 ALLOWABLE FIN TEMPERATURE VS. AVERAGE ON-STATE CURRENT (SINGLE-PHASE HALF WAVE) 160 150 ON-STATE POWER DISSIPATION (W) FIN TEMPERATURE (C) 140 130 120 110 100 90 80 70 = 30 60 360 RESISTIVE, INDUCTIVE LOAD 360 3500 RESISTIVE, 3000 INDUCTIVE LOAD 2500 2000 1500 1000 500 0 0 200 400 600 60 = 30 90 180 120 90 120 180 800 1000 60 0 200 400 600 800 1000 AVERAGE ON-STATE CURRENT (A) AVERAGE ON-STATE CURRENT (A) ON-STATE POWER DISSIPATION (W) MAXIMUM ON-STATE POWER DISSIPATION CHARACTERISTICS (RECTANGULAR WAVE) 4000 3500 270 DC ALLOWABLE FIN TEMPERATURE VS. AVERAGE ON-STATE CURRENT (RECTANGULAR WAVE) 140 130 FIN TEMPERATURE (C) 3000 2500 2000 1500 1000 500 0 0 400 800 = 30 90 60 120 120 110 100 90 80 70 60 50 = 30 60 360 RESISTIVE, INDUCTIVE LOAD 180 360 RESISTIVE, INDUCTIVE LOAD 270 DC 120 90 180 1200 1600 40 0 400 800 1200 1600 2000 AVERAGE ON-STATE CURRENT (A) AVERAGE ON-STATE CURRENT (A) 8000 TURN ON TIME tgt, TURN ON DELAY TIME td (s) GATE TRIGGER CURRENT VS. JUNCTION TEMPERATURE (TYPICAL) GATE TRIGGER CURRENT (mA) 7000 6000 5000 4000 3000 2000 1000 0 -60 -20 20 VD = 5 ~ 20V IT = 25 ~ 200A HALF SINE WAVE TURN ON TIME, TURN ON DELAY TIME VS. TURN ON GATE CURRENT (TYPICAL) 10.0 9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 0 0 10 20 30 40 50 60 70 80 90 100 TURN ON GATE CURRENT (A) td IT = 3300A VD = 1250V diT/dt = 500A/s diG/dt = 10A/s Tj = 125C tgt 60 100 140 JUNCTION TEMPERATURE (C) Aug.1998 MITSUBISHI GATE TURN-OFF THYRISTORS FG3300AH-50DA HIGH POWER INVERTER USE PRESS PACK TYPE TURN OFF TIME tgq, TURN OFF STORAGE TIME ts (s) TURN OFF TIME tgq, TURN OFF STORAGE TIME ts (s) TURN OFF TIME, TURN OFF STORAGE TIME VS. TURN OFF CURRENT (TYPICAL) 40 35 30 25 ts tgq TURN OFF TIME, TURN OFF STORAGE TIME VS. RATE OF RISE OF TURN OFF GATE CURRENT (TYPICAL) 80 70 60 50 40 30 20 10 0 0 10 20 30 40 50 ts tgq VD = 1250V VDM = 1875V IT = 3300A VRG = 17V CS = 6.0F LS = 0.2H Tj = 125C 20 15 10 5 0 0 1000 2000 VD = 1250V VDM = 1875V diGQ/dt = -40A/s VRG = 17V CS = 6.0F LS = 0.2H Tj = 125C 3000 4000 60 70 80 TURN OFF CURRENT (A) RATE OF RISE OF TURN OFF GATE CURRENT (A/S) TURN OFF GATE CURRENT VS. TURN OFF CURRENT (TYPICAL) TURN OFF GATE CURRENT (A) TURN OFF GATE CURRENT (A) VD = 1250V 1400 VDM = 1875V diGQ/dt = -40A/s VRG = 17V 1200 CS = 6.0F LS = 0.2H 1000 Tj = 125C TURN OFF GATE CURRENT VS. RATE OF RISE OF GATE CURRENT (TYPICAL) 1000 1600 900 800 800 600 400 200 0 0 1000 2000 3000 4000 700 600 500 VD = 1250V VDM = 1875V IT = 3300A VRG = 17V CS = 6.0F LS = 0.2H Tj = 125C 20 30 40 50 60 TURN OFF CURRENT (A) RATE OF RISE OF TURN OFF GATE CURRENT (A/S) TURN ON SWITCHING ENERGY (MAXIMUM) 4.0 SWITCHING ENERGY Eon (J/P) SWITCHING ENERGY Eoff (J/P) VD = 1250V IGM = 40A 3.5 diG/dt = 10A/s CS = 6.0F 3.0 LS = 0.2H Tj = 125C TURN OFF SWITCHING ENERGY (MAXIMUM) 8 7 6 5 4 3 2 1 0 0 1000 2000 VD = 1250V VDM = 1875V diGQ/dt = -40A/s VRG = 17V LS = 0.2H Tj = 125C CS = 4.0F 5.0F 6.0F 2.5 2.0 diT/dt = 500A/s 1.5 1.0 0.5 0 0 1000 2000 300A/s 100A/s 3000 4000 5000 3000 4000 TURN ON CURRENT (A) TURN OFF CURRENT (A) Aug.1998 |
Price & Availability of FG3300AH-50DA |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |